SVX Safe Area Energized to Close (CE228)

Electric

SVX Hazardous Area Energized to Open (CE239)

SVX Hazardous Area Energized to Open (CE239)

Hazardous area rating: 11 2 G D IP66 EEx e II T4
Electric solenoids: 12 VDC Pull: 46A Hold: 1.1A
  24 VDC Pull: 25A Hold: 0.5A
Valve body size: 3" (76mm) 5" (127mm) 8" (203mm)
HAX hose adaptors 1½" - 4" (38-102mm) 3½" - 6" (89-152mm) 7" - 8" (178-203mm)

 

SVX Hazardous Area Manual Override

SVX Hazardous Area Manual Override, Energized to Latch Open (CE230)

Hazardous area rating: 11 2 G D IP66 EEx e II T4
Electric solenoids: 12 VDC Hold: 1.1A
  24 VDC Hold: 0.5A
Valve body size: 3" (76mm) 5" (127mm)
HAX hose adaptors: ½"-4" (38-102mm) 3½"-6" (89-152mm)

 

SVX Safe Area Energized to Open Model

SVX Safe Area Energized to Open (CE240)

Actuation methods: Energize to Run
Electric solenoids:

12 VDC

24 VDC

Pull: 46A

Pull: 25A

Hold: 1.1A

Hold: 0.5A

Valve body size: 3" (76mm) 5" (127mm) 8" (203mm)
Hose adapter size: 1½"-4" (38-102mm) 3½"-6" (89-152mm) 7"-8" (178-203mm)
SVX Safe Area Energized to Close (CE228)

SVX Safe Area Energized to Close (CE228)

Actuation methods: Power to close / Manual reset by handle
Electric solenoids: 2 wire with automatic pull to hold internal switching. 12V or 24V options
Valve body size: 3" (76mm) 5" (127mm) 8" (203mm)
Hose adapter size: 1½"-4" (38-102mm) 3½"-6" (89-152mm) 7"-8" (178-203mm)
SVR-2XX Compact ButterflyValve

SVR-2XX Compact Butterfly Valves

SVR-3XX Compact Butterfly Valve

SVR-3XX Compact Butterfly Valves

Chalwyn XT Butterfly Valve

XT Butterfly Valve

Standard Materials

Valve/disc

Seals

Solenoid housing

Anodised aluminium

Viton/Nitrile

Plated steel

Electric Solenoid

12 VDC

 

26.4 Amps (max) @ 13.2 VDC / -40°C

19.8 Amps (max) @ 13.2 VDC / 25°C

24 VDC

 

13.2 Amps (max) @ 26.4 VDC / -40°C

9.9 Amps (max) @ 26.4 VDC / 25°C

Intake & ambient air temperature Minimum: -40°C / -20°C (based on valve selection) maximum: 125°C
Max charge air pressure
5.0 bar (72 psi)
Switch rating
4.4 Amps DC maximum